GE MAC 5000
EKG Machines
- Description
- Specification
- Documents
Description
GE Marquette Mac 5000 Features
GE’s premier ECG system, the MAC 5000, offers gender-specific interpretive software as well as adult and pediatric interpretation. With a compact design for easy operation to increase productivity, the MAC 5000 is part of GE’s solutions for networked, noninvasive testing.
The MAC 5000 Resting ECG System delivers the advanced capabilities that only the industry’s most extensive collection of proven algorithms can offer. The MAC 5000 provides the sophistication required for advanced ECG applications, while its advanced algorithm capabilities include true, 12-lead ECG computer analysis and interpretation.
- Delivers advanced disease management capabilities.
- Uniquely delivers seamless connectivity to the information system for data storage and retrieval of ECGs.
- Ultimate resting ECG system.
Specifications
Processing
ECG Interpretation
- 12SL™ Adult and Pediatric ECG Analysis Program
Computerized Measurements
- 12SL™ Adult and Pediatric ECG Analysis Program
Optional
- PHI-RES™ & HI-RES™ Late Potential Analysis
Additional ECG Function
- Vectorcardiography
ECG Analysis Frequency
- 500 samples/second (sps)
ECG Storage
- 150 typical
- 200 ECGs maximum on removable media (1.44 MB, 3.5diskette)
Digital Sampling Rate
- 4000 samples / second / channel
Pre-Acquisition
- Provides 10 seconds of instantaneous ECG acquisition
AC Differential
- ±10 mV DC offset: ±320 mV
Resolution
- 4.88 µV/LSB @ 500 sps
Frequency Response
- –3 dB @ 0.01 to 150 Hz
Common Mode Rejection
- >140 dB (123 dB with AC filter disabled)
Input Impedance
- >10M@ 10 Hz, defibrillator protected
Patient Leakage
- <10 µA
Pace Detect
- Orthogonal LA, LL and V6; 750 µV @ 50 µs
Special Acquisition Functions
- Disconnected lead detection
- Electrode impedance
- Excessive AC noise
- Baseline wander and muscle tremor messages
Heart Rate Meter
- 30 to 300 BPM ± 10% or 5 BPM whichever is greater. Heart rates outside this range will not be displayed
Display
Display Type
- 264 mm (10.4 in) diagonal graphics backlit AM LCD
Display Resolution
- 640 x 480 pixels with waveform enhancement
Display Data
- Heart rate
- Patient name
- ID
- Clock
- Waveforms
- Lead labels
- Speed
- Gain and filter settings
- Warning messages
- Prompts and help messages
Writer
Writer Technology
- Thermal dot array
Writer Speeds
- 5 mm/s
- 12.5 mm/s
- 25 mm/s
- 50 mm/s (same as display)
Number of Traces
- 3
- 6
- 12
- 15
- user selectable (same as display)
Writer Sensitivity / Gain
- 2.5, 5, 10, 20, 10/5 (split calibration) mm/mV (same as displayed)
Writer Speed Accuracy
- ±2%
Writer Amplitude Accuracy
- ±5%
Writer Resolution
- Horizontal 1000 dpi @ 25 mm/s
- 200 dpi vertical
Paper Type
- Thermal, Z-fold, perforated, fan fold, 300 sheets/pack
Paper Size
- A size: 214.63 mm x 280 mm (8.45 in x 11 in)
- A4 size: 210 mm x 297.5 mm (8.27 in x 11.7 in)
Additional information
Manufacturer | |
---|---|
Name | |
Part Number | MAC 5000 |
Specialty | |
Product Type |