Valleylab SurgiStat II
Type: Electrosurgical Unit
Make: Valleylab
Model: SurgiStat II
Condition: Refurbished
Availability: In-Stock
Status: Supported by Denova Medical, Inc.
- Description
- Specification
- Documents
Description
Â
Valleylab Surgistat II Descriptions
Â
For general electrosurgery needs in the office, clinic, or emergency room, the Valleylab SurgiStatâ„¢ II generator provides exceptional performance, reliability, and safety benefits in a compact, easy to use unit.
Â
Â
Â
- Easy and quick to set up; compact and light
- Saves time with automatic access to previously used power settings and modes
- Provides precise surgical effect with power control dials
- Performs most common office-based electrosurgical procedures
- Provides ability to change power settings while activating the generator
- Includes both monopolar and bipolar outputs
- Accepts preferred accessories:
- standard 3-pin pencil, most standard footswitching devices (with adapter), and standard Valleylab monopolar footswitch (optional)
- standard 2-pin bipolar footswitching devices
- Manufactured to the highest standards of quality in electrosurgical technology
- Ensures consistent clinical performance over a variety of procedures
- Increased patient safety with a return electrode contact quality monitoring system (RECQMS). The RECQMS system continually monitors patient impedance levels and deactivates the generator if a fault in the patient/return electrode contact is detected
Â
Â
Dimensions
- Height: 14 cm (5.5 in)
- Width: 26 cm (10.25 in)
- Depth: 25.4 (10 in)
- Weight: <6.5kg (<14 lbs)
Â
RF Leakage
- Bipolar <39 Arms
- Monopolar <150 Arms
Â
Input Power
- 110-120 Volts at 60 Hz
Â
PER = 86
- PER (Power Efficiency Rating) is the measure of an electrosurgical generator’s ability to accurately deliver the selected power into a wide range of tissue types.
Â
Controls and Indicators
- Mode Selection: Separate pushbuttons select modes (Cut or Blend, Desiccate, Fulgurate, or Bipolor)
- PowerSetting: Dials adjust power in increments of 1 watt
- Audible Tones: A continuous tone indicates activation; volume control is on the back panel. A dual tone, which is not adjustable, indicates an alarm condition; for example, compromised patient return electrode contact
Â
Receptacles
- Front Panel: RECQMS patient return electrode receptacle (RECQMS system requires a split plate patient return electrode)
- Receptacle for standard footswitching devices with adapters
- Receptacle for standard 2-pin bipolar footswitching devices
Â
Rear Panel
- Receptacle for standard Valleylab monopolar footswitch
Additional information
Manufacturer | |
---|---|
Name | |
Part Number | SurgiStat II |
Specialty | |
Maximum Cut Power | |
Product Type | |
Cut Frequency | |
Cut Modes | |
Maximum_Coagulation_Power | |
Coag Frequency kHz | |
Coagulation Modes | |
Bipolar Output Power | |
Bipolar Frequency | |
Type | |
Return Electrode Monitoring |